Daily Report: August 21, 2025
8/21/25Mukti
Conducted training for Walfred and Nayeli on the strut leak-down test procedure, demonstrating correct disassembly and validation steps to ensure waterproofing integrity.
Process included careful removal of the strut head using plastic-tip pliers, loosening screws in an X-pattern, and inspecting connector interfaces for sealing issues.
Emphasized verification of connector housings to ensure they are fully potted and free of voids, preventing water ingress and electrical failures.
Documented the procedure with photos for inclusion in the assembly and packaging binder, supporting standardization across the team.
Provided an update on strut testing results: two out of six struts exhibited persistent leakage despite replacing cables and the strut plug body cover. Failures […more]